§25-6.9 Preliminary Plat of a Major Site Plan.
| |||||||
a. Required Documents. Prior to issuance of a Certificate of Completeness of scheduling of a preliminary plat of a major site plan for public hearing, the Administrative Officer shall determine that the following has been submitted in proper form:
| |||||||
1. Borough Engineer's Report.
| |||||||
2. Copy of application for granting; of a CAFRA Permit, where required and if submitted.
| |||||||
3. Application for State Wetlands Permit, where required.
| |||||||
4. Other submittals that may be required by the Borough Engineer, Planning Board, Board of Adjustment, or Federal, State or local law.
| |||||||
5. The application for development for a preliminary plat of a major site plan shall include a request for the granting of any variances required.
| |||||||
6. Required application fees.
| |||||||
7. Fifteen (15) copies of a plat and attachments meeting the requirements set forth below.
| |||||||
b. Plat Requirements.
| |||||||
1. General Requirements.
| |||||||
(a) Any preliminary plat of a major site plan presented to the Planning Board or Board of Adjustment for its approval shall be signed and appropriately sealed by an architect, professional engineer, land surveyor and/or professional planner licensed to practice in the State of New Jersey: provided, however, that sanitary sewer, water distribution and storm drainage plans and water anti sewage treatment plans may only be signed and sealed by a professional engineer.
| |||||||
(b) Site plans shall not be drawn at a scale smaller than one inch equals fifty (1" = 50') feet nor larger than one inch equals ten (1" = 10') 1 feet. If the size of the site would require the use of sheets larger then thirty inches by forty-two (30" x 42") inches in order to show the entire site on one (1) sheet, the detailed information for the site plan shall be shown in sections on sheets not larger than thirty inches by fortytwo (30" x 42".) inches, which sheets shall be keyed to an overall plan of the site drawn at a scale of not less than one inch equals two hundred (1" = 200') feet.
| |||||||
The site plan shall be based on a monumented, current certified boundary survey. The date of the survey and the name of the person making same shall be shown on the map. If twelve (12) months or more has passed since the date of (or date of last recertification of) the survey, it shall be recertified- and if necessary, brought up to date. | |||||||
2. Title Block. The title block shall appear on all sheets and include:
| |||||||
(b) Name of the development, if any.
| |||||||
(c) Tax map sheet, block and lot number of the site, as shown on the latest Borough Tax Map, the date of which should also be shown.
| |||||||
(d) Date (of original and all revisions).
| |||||||
(e) Names and addresses of owner and developer, so designated.
| |||||||
(f) Name(s), signature(s), address(es), and license number(s) of engineer, architect, land surveyor or planner who prepared the plan and their embossed seal.
| |||||||
(g) If the site plan contains more than one (1) sheet, each sheet shall be numbered and titled.
| |||||||
3. A schedule shall be placed on the site plan indicating:
| |||||||
(a) The acreage of the tract and site (the portion of the tract involved in the site plan).
| |||||||
(b) The floor area of the existing and proposed buildings (listed separately).
| |||||||
(c) The proposed use or uses and the floor area devoted to each use.
| |||||||
(d) The zone in which the site is located.
| |||||||
(e) Proposed and required lot dimensions and front, rear and side setbacks.
| |||||||
(f) Proposed and required off-street parking spaces.
| |||||||
(g) Square footage and percentage of the site retained in unoccupied open space and occupied by buildings.
| |||||||
4. North arrow and written and graphic scales.
| |||||||
5. The tops of the banks and boundaries of the floodways and flood hazard areas of all existing watercourse, where such have been delineated or the limits of alluvial soils where the boundaries of floodways and flood hazard areas have not been determined, and/or such other information as may assist the Board in the determination of floodway and flood hazard area limits.
| |||||||
6. Paving and right-of-way widths of existing streets within two hundred (200') feet of the site.
| |||||||
7. The boundary, nature and extent of wooded area, swamps, bogs and ponds within the site and within two hundred (200') feet thereof.
| |||||||
8. Existing and proposed manholes, sewer lines, fire hydrants, water lines, utility poles and all other topographical features of a physical or engineering nature within the site and within two hundred (200') feet thereof.
| |||||||
9. All existing structures on the site and within two hundred (200') feet thereof, including their use, indicating those to be destroyed or removed and those to remain.
| |||||||
10. Location, use, finished grade level, ground coverage, first floor and basement elevations, front, rear and side setbacks of all existing buildings and other pertinent improvements.
| |||||||