19-5.23 I-2 INDUSTRIAL DISTRICT.

19-5.2301 Primary Intended Use.

This zone is designed for offices for business, professional, executive or administrative purposes, scientific or research laboratories and industrial and manufacturing uses as well as anything permitted in the I-1 Zone, provided, however, retail sales and services are specifically prohibited (Ord. #2-77, 19-5.2301)

19-5.2302 Prohibited Use.

No land or building shall be used or occupied for any use which is prohibited in subsection 19-5 2202 (Ord #2-77, 19-5 2302)

19-5.2303 Required Conditions.

a. Height No structure shall exceed a height of two (2) stories provided the building is not higher than thirty (30') feet.

b. Front Yard There shall be a front yard of not less than seventy-five (75') feet. Off-street parking is permitted in the front yard as regulated in subsection 19-5.803 f.



c. Side Yard There shall be two (2) side yards and no side yard shall be at less than twenty (20%) percent of the average lot width provided in no event shall any side yard be less than twenty (20') feet. Off-street parking is permitted in the side yard, provided the parking area is no closer than ten (10') feet to any property line, nor five (5') feet to any building.

d. Bear Yard There shall be a rear yard of not less than seventy-five (75') feet Where an alley or railroad right-of-way abuts the rear of the property, such space may be counted as part of the rear yard. Off-street parking is permitted in the rear yard, provided the parking area is no closer than ten (10') feet to any property line, nor five (5') feet to any building.

e. Special District Boundary Buffer Area No building shall be built within one hundred (100') feet of any residence zone line and off-street parking and access drives shall be set back thirty (30') feet from such zone line to establish a buffer area as defined herein. Said buffer area shall be suitably landscaped as approved by the Planning Board

f. Lot Area Each lot in the I-2 Industrial District shall contain a minimum lot area of at least two (2) acres and shall have a frontage at the front street property line of at least two hundred (200') feet

g. Maximum Floor Area Ratio The gross floor area of all floors of all buildings shall not exceed twenty-five (25%) percent of the total lot area.

h. Landscaping The requirements of subsection 19- 5.2103 h shall be met

Before the issuance of a building or occupancy permit, the Planning Board shall review and approve a site development plan of the proposed use and shall ascertain that all the requirements of this Section are complied with (Ord, #2-77, 19-5 2303, Ord #28-81, 11)

19-5.2304 Procedure for Building and Occupancy Permits.

The procedure of subsection 19-5 2204 shall be followed for all industrial uses hereinafter erected, (Ord #2-77, 195.2304)

19-5.2305 Performance Standards.

Before the issuance of any building or occupancy permit for any use in the I-2 District, all performance standards of the 1-1 District, as regulated in subsection 19-5.2205 shall be complied with (Ord. #2-77, 19-5 2305)

19-5.2306 Permitted Accessory Uses.

Permitted accessory uses are established as follows:

a. The Installation of wireless telecommunications antennas on existing structures subject to minor site plan approval pursuant to Section 19-4.1405A. and consistent with Visual Compatibility Requirements of Section 19-5.726 of this Chapter.

**Webmasters Note: The previous subsection has been added as per Ordinance No. 3-99.

19-5.2307 Permitted Conditional Uses.

Permitted conditional uses are established as follows:

a. Wireless telecommunications towers in compliance with Section 19-5.726a(2), (3) and (4) and Section 19-5.1009 of this Chapter.

**Webmasters Note: The previous subsection has been added as per Ordinance No. 3-99.