§ 228-303 CONFLICTS

All other ordinances, parts of ordinances, or other local requirements that are inconsistent or in conflict with this ordinance are hereby superseded to the extent of any inconsistency or conflict, and the provisions of this ordinance apply.

§ 228-304 SEVERABILITY

This Ordinance shall be so construed as not to conflict with any provision of New Jersey or Federal law. Notwithstanding that any provision of this Ordinance is held to be invalid or unconstitutional by a court of competent jurisdiction, all remaining provisions of the Ordinance shall continue to be of full force and effect. The provisions of this Ordinance shall be cumulative with, and not in substitution for, all other applicable zoning, planning and land use regulations.



**Webmasters Note: The previous Article has been added as per Ordinance No. 09-10.

Schedule A SITE PLAN CHECKLIST

( ) Original and 14 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent

( ) 15 complete sets of plans (site plan, lighting, details, etc.)

( ) 11 copies of site plan (excluding details and construction plans)

( ) Plans collated, stapled, folded to a dimension not to exceed IO " x 12

( ) Application fee

( ) Escrow fee

( ) Signed escrow release form

( ) Signed authorization form

( ) Three (3) complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) Survey of property, prepared by a licensed surveyor of the State of New Jersey showing:

a. Boundaries of the property

b. Building and setback lines and the lines of all existing streets, roads, reservations, casements, right-of-ways and areas dedicated to public use, within two hundred (200) feet of the property

c. Title, reference meridian, scale

d. Name and address of record owner

e. Name, address, professional license number and seal of the surveyor who prepared the survey

The following shall be on the plans submitted:



( ) Key map showing site and its relation to surrounding area

( ) Plans certified by appropriate professional as stipulated by New Jersey revised statutes Title 45:8, 13:40-7.1 et seq

( ) Zone data

( ) Location of all existing and proposed buildings or structures with spot elevations

( ) Names of all owners of record of all adjoining property, and property directly across the street or streets from the property involved, and the block and lot numbers of all the property shown on the plan

( ) Existing and proposed contours at I foot intervals based on National Geodetic Vertical Datum 1988

[1929] to determine general slope and natural drainage of the land. Where necessary to evaluate drainage, the Board shall require contours to be shown for all lands within 200 feet of the property in question.

( ) Existing and proposed easements

( ) All existing schools, zoning and special district boundaries within two hundred (200) feet of the property. Such features shall be shown on a separate map or as a key map on the detailed map itself.

( ) The distances, as measured along the centerlines of existing streets abutting the property to the nearest intersection with any public street

( ) Location of existing edge of pavement and proposed edge of pavement of all roadways abutting site

( ) Location of all existing and proposed storm drainage structures and utility lines including telephone, power, water, sewer, gas, etc., whether publicly or privately owned, with pipe sizes, grades and direction of flow

( ) Proposed use or uses of land and buildings, including outdoor storage

( ) Size and location of all driveways and curb cuts

( ) Cross sections and construction details of all streets, pavement, curb, sidewalks and walkways

( ) Parking and loading layout

( ) Total number of parking or loading spaces

( ) Dimensions of parking or loading spaces, aisles and parking islands

( ) Dimensions of all building setbacks and yards

( ) Percent total impervious coverage

( ) Percent total building coverage

( ) Building dimensions

( ) Area and height of proposed and existing buildings or structures

( ) Building elevations (each side) indicating materials to be used in construction

( ) Location, direction of illumination and intensity of all outdoor lighting. Type of fixture and height of lighting are to be indicated and isolux lines are to be superimposed on the plan.

( ) Manufacturers catalogue cut sheet for proposed lighting

( ) The location, size, materials and construction details of existing and proposed signs

( ) Existing and proposed screening and landscaping, including a planting plan, with quantity, species, caliper and location of planting noted in accordance with Chapter 192

( )

[

Existing wooded areas] Location of existing trees with caliper of 4 inches dbh or more

( ) Name, address, professional license number and seal of the architect, engineer, planner-or surveyor preparing the site plan

( ) Refuse enclosure location and detail

( ) Fencing detail

( ) Percolation test and soil log results (if applicable)

( ) Soil type

( ) Evidence of soil erosion and sediment control plan submittal to Freehold Soil Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Transportation for Route 18 Access Permit and Drainage Permit (Route 18 properties only)



( ) Traffic study, including anticipated traffic volumes, capacity of existing or proposed roads, traffic impact on road network and need for traffic improvements

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit (if applicable)

( ) A Letter of Interpretation from New Jersey Department of Environmental Protection Freshwater Wetlands Division, including evidence that notice was given to the Municipal Clerk pursuant to N.J.S.A. 13:9B. If the New Jersey Department of Environmental Protection deems that wetlands are present, or the applicant does not receive a response to its request for a letter of interpretation, the applicant shall show such areas on a survey of the property, prepared by a Licensed Surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Storm drainage calculations in accordance with Chapter 192

( ) Environmental Impact Assessment Report in accordance with Town Code Section 132-31

( ) Copy of any protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) "Letter of Intent" detailing size of proposed building, proposed use, number of tenants, number of employees, anticipated hours of operation, traffic, etc.

( ) Such other items and information pertaining to the site as the Department of Planning and Engineering reasonably determines would be necessary or helpful to the Planning Board in reviewing the application.

( ) Recycling Plan, which shall include details as to the storage, collection, disposition and recycling of recyclable materials as listed in Chapter 114

( ) Site map including site layout and pertinent site features on CAD-generated data file submitted on diskette(s), 3.50"/1.44Mb formatted for DOS Version 3.x based IBM PC's and PC compatibles. The file shall be either the most current version AutoCAD drawing file compatible or a DXF format drawing interchange file compatible with AutoCAD.

MINOR SUBDIVISION CHECKLIST

( ) Original and 14 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent

( ) 15 complete sets of sketch plat

( ) 11 copies of lot layout (excluding details and construction plans)

( ) Scale not less than 1" to 100'

( ) Plans collated, stapled, folded to a dimension not to exceed 10" x 12"

( ) Plans no greater than 36" x 42" size

( ) Application fee

( ) Escrow fee

( ) Signed escrow release form

( ) Signed authorization form

( ) Three (3) complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue off-ice for verification that no delinquent taxes or assessments are due

( ) Percolation test and soil log results (if applicable) certified by New Jersey Licensed Professional Engineer

( ) Soil type

( ) Evidence of soil erosion and sediment control plan submittal to Freehold Soil Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Transportation for Route 18 Access Permit and Drainage Permit (Route 18 properties only)

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit (if applicable)

( ) A statement indicating that the property which is the subject of the application for development is free of delineation as a freshwater wetland, as more particularly defined in N.J.S.A. 13:913-3 et seq, or if any part of the property which is the subject of the application for development is delineated as "freshwater wetland", then the applicant shall show such areas on a survey of the property, prepared by a licensed surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Copy of any protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) A written statement setting forth the intentions of the applicant in regard to the proposed character of the subdivision, whether for the sole purpose of the sale of land or for the construction and sale of homes, with data as to the number, price range, size, floor plan and the outside design of homes, deed restrictions, date of beginning and completion of construction and proposed method of maintaining parking or recreational areas. The statement shall also contain an acknowledgment that the applicant is familiar with the Township's Look Alike Ordinance and Tree Removal Ordinance and will abide by the terms of both ordinances.

( ) Such other items and information pertaining to the site as the Department of Planning and Engineering reasonably determines would be necessary or helpful to the Planning Board in reviewing the application.

The following shall be on the plans submitted:

( ) Key map showing site and its relation to surrounding area

( ) Entire tract shown on one sheet

( ) Plat based on a new or existing survey of the property being subdivided, tied into N.J. State plane coordinate system of 1983 as per revised statutes title 45:8

( ) Location of that portion which is to be subdivided in relation to the entire tract

( ) Plans signed and sealed by a New Jersey Licensed Land Surveyor (survey data only) and by a New Jersey Licensed Professional Engineer if engineering has been performed

( ) Zone data table

( ) The tract name, tax map sheet, block and lot number, date, reference meridian, scale and the following names and addresses:

( ) The record owner or owners

( ) The subdivider

( ) The person who prepared the map

( ) Acreage of tract to be subdivided to the nearest hundredth of an acre

( ) Accurate length of all existing and proposed lot lines

( ) Proposed lot lines



( ) Existing lot lines to remain

( ) Existing lot lines to be removed

( ) Minimum building setback line on all lots

( ) Existing and proposed wells or sanitary sewer systems on tract

( ) Area of existing and proposed lots to the nearest 100th of an acre

( ) Existing and proposed streets, sidewalks, storm drains, radii, curbs, bridges, culverts

( ) Setback distance of all existing and proposed structures from each lot line

( ) Natural features, such as wooded areas and rock formations

( ) Existing and proposed structures

( ) Existing and proposed screening and landscaping, including a planting plan, with quantity, species, caliper and location of planting noted in accordance with Chapter 192

( ) All existing schools, zoning and special district boundaries within two hundred (200) feet of the property. Such features shall be shown on a separate map or as a key map on the detailed map itself.

( ) All lot lines, streets, roads, streams, wooded areas and other physical features on or within two hundred (200) feet of the extremities of the proposed subdivision and the existing land use of all adjacent land.

( ) Location of existing trees with caliper of 4 inches d.b.h. or more

( ) Existing and proposed contours at 2 foot intervals based on National Geodetic Vertical Datum 1988

[

1929] to determine general slope and natural drainage of the land. Where necessary to evaluate drainage, the Board shall require contours to be shown for all lands within 200 feet of the property in question.

( ) Existing and proposed easements (sight triangle included)

( ) The distances, as measured along the centerlines of existing streets abutting the property to the nearest intersection with any public street

( ) Location of existing edge of pavement and proposed edge of pavement of all roadways abutting site

( ) Location of existing right-of-way lines (both sides) of all streets abutting the subdivision

( ) Location of all existing and proposed storm drainage structures and utility lines including telephone, power, water, sewer, gas, etc., whether publicly or privately owned, with pipe sizes, grades and direction of flow

( ) Names of all owners of record of all adjoining property, and property directly across the street or streets from the property involved, and the block and lot numbers of all the property shown on the plan

( ) Location of all land which lies within the I 00 year flood line as depicted on the current State of New Jersey, Department of Environmental Protection, Division of Water Services, Bureau of Flood Plain Management. Delineation of Flood way and Flood Hazard Area Maps.

( ) Location of all areas with seasonal high-water table at the surface, including lakes and ponds. Location of all areas with seasonal high water table within one and a half (1-1/2) feet of the surface.

( ) Subdivision map including site layout and pertinent site features on CAD-generated data file submitted on diskette(s), 3.50"/1.44Mb formatted for DOS Version 3.x based IBM PC's and PC compatibles. The file shall be either the most current version AutoCAD drawing file compatible o a DXF format drawing interchange file compatible with AutoCAD.

PRELIMINARY SUBDIVISION CHECKLIST

( ) Original and 14 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent

( ) 15 complete sets of preliminary plat

( ) 11 copies of lot layout (excluding details and construction plans)

( ) Scale not less than 1" to 100'

( ) Plans collated, stapled, folded to a dimension not to exceed IO" x 12"

( ) Plans no greater than 36" x 42" size

( ) Application fee

( ) Escrow fee



( ) Signed escrow release form

( ) Signed authorization form

( ) Three (3) complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) Percolation test and soil log results (if applicable) certified by New Jersey Licensed Professional Engineer

( ) Soil type

( ) Evidence of soil erosion and sediment control plan submittal to Freehold Soil Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Transportation for Route 18 Access Permit and Drainage Pen-nit (Route 18 properties only)

( ) Traffic study, including anticipated traffic volumes, capacity of existing or proposed roads, traffic impact on road network and need for traffic improvements

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit (if applicable)

( ) A Letter of Interpretation from N.J. Dept. of Environmental Protection Freshwater Wetlands Division, including evidence that notice was given to the Municipal Clerk pursuant to N.J.S.A. 13:9B. If the N.J. Dept. of Environmental Protection deems that wetlands are present, or the applicant does not receive a response to its request for a letter of interpretation, the applicant shall show such areas on a survey of the property, prepared by a Licensed Surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Storm drainage calculations, in accordance with Chapter 192

( ) Environmental Impact Assessment Report in accordance with this chapter

( ) Copy of any protective covenants or deed restrictions that are intended to cover all or any part, of the tract

( ) A written statement setting forth the intentions of the applicant in regard to the proposed character of the subdivision, whether for the sole purpose of the sale of land or for the construction and sale of homes, with data as to the number, price range, size, floor plan and the outside design of homes, deed restrictions, date of beginning and completion of construction and proposed method of maintaining parking or recreational areas. The statement shall also contain an acknowledgment that the applicant is familiar with the Township's Look Alike Ordinance and Tree Removal Ordinance and will abide by the terms of both ordinances.

( ) Such other items and information pertaining to the site as the Department of Planning and Engineering reasonably determines would be necessary or helpful to the Planning Board in reviewing the application.

The following shall be on the plans submitted:

( ) Key map showing site and its relation to surrounding area

( ) Plat based on a new or existing survey of the property being subdivided, tied into N.J. State plane coordinate system of 1983 as per revised statutes title 45:8

( ) Plans signed and sealed by a New Jersey Licensed Land Surveyor (survey data only) and by a New Jersey Licensed Engineer if engineering has been performed

( ) Zone data table

( ) The tract name, tax map sheet, block and lot number, date, reference meridian, scale and the following names and addresses:

( ) The record owner or owners

( ) The subdivider

( ) The person who prepared the map

( ) Acreage of tract to be subdivided to the nearest hundredth of an acre

( ) Proposed lot lines

( ) Existing lot lines to remain

( ) Existing lot lines to be removed

( ) Setback distance of all existing and proposed structures from each lot line

( ) Area of lots shown to nearest square foot

( ) Existing and proposed streets, sidewalks, storm drains, radii, curbs, bridges, culverts

( ) Natural features, such as wooded areas and rock formations



( ) Existing and proposed structures

( ) Existing and proposed screening and landscaping, including a planting plan, with quantity, species, caliper and location of planting noted in accordance with Chapter 192

( ) All existing schools, zoning and special district boundaries within two hundred (200) feet of the property. Such features shall be shown on a separate map or as a key map on the detailed map itself.

( ) Location of existing trees with caliper of 4 [6] inches d.b.h. or more

( ) Existing and proposed contours at I foot intervals based on National Geodetic Vertical Datum 1988 [1929] to determine general slope and natural drainage of the land. Where necessary to evaluate drainage, the Board shall require contours to be shown for all lands within 200 feet of the property in question.

( ) High and low points of all proposed streets, proposed cross sections and centerline profiles of all proposed streets

( ) Existing and proposed easements

( ) The distances, as measured along the centerlines of existing streets abutting the property to the nearest intersection with any public street

( ) Location of existing edge of pavement and proposed edge of pavement of all roadways abutting site

( ) Location of all existing and proposed storm drainage structures and utility lines including telephone, power, water, sewer, gas, etc., whether publicly or privately owned, with pipe sizes, grades and direction of flow

( ) Names of all owners of record of all adjoining property, and property directly across the street or streets from the property involved, and the block and lot numbers of all the property shown on the plan

( ) Plans and profiles of all proposed utility layouts, including storm drainage, sanitary sewers and waterlines, showing feasible connections to existing utility systems or to proposed systems, which will be installed before the plat is submitted for final approval

( ) Statement of the steps to be taken by the subdivider to eliminate any downstream drainage problems which may be caused by the development of the subdivision and to mitigate impact from prior upstream development

( ) If fixtures other than Public Service Electric and Gas or Jersey Central Lighting, the location, direction of illumination and intensity of all outdoor lighting. Type of fixture and height of lighting are to be indicated and isolux lines are to be superimposed on the plan.

( ) Manufacturers catalogue cut sheet for proposed lighting

( ) Location of all land which lies within the I 00 year flood line as depicted on the current State of New Jersey, Department of Environmental Protection, Division of Water Services, Bureau of Flood Plain Management, Delineation of Flood way and Flood Hazard Area Maps.

( ) Location of all areas with seasonal high-water table at the surface, including lakes and ponds.

( ) Location of all areas with seasonal high water table within one and a half (1-1/2) feet of the surface.

( ) Environmental Risk Audit (ERA) in accordance with Township Code Chapter

[192] 132-58.1 I(2)

( ) Recycling Plan, which shall include details as to the storage, collection, disposition and recycling of recyclable materials as listed in Chapter 1 14

( ) Subdivision map including site layout and pertinent site features on CAD-generated data file submitted on diskette(s), 3.50"/1.44Mb formatted for DOS Version 3.x based IBM PC's and PC compatibles. The file shall be either the most current version AutoCAD drawing file compatible o a DXF format drawing interchange file compatible with AutoCAD.

FINAL SUBDIVISION & FINAL P.U.R.D. CHECKLIST

( ) Original and 14 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent

( ) 26 complete sets of final plat

( ) Scale not less than 1" to 100'

( ) Plans collated, stapled, folded to a dimension not to exceed 10" x 12"

( ) Plans no greater than 36" x 42" size

( ) Application fee

( ) Escrow fee

( ) Signed escrow release form

( ) Signed authorization form

( ) Three (3) complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) Copy of protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) Final map on CAD-generated data file submitted on CD-ROM, diskette(s),

[either 5.25"/360K or] 3.50"/1.44Mb formatted

[for DOS Version 3.x based] IBM PC's and PC compatibles. The file shall be either the most current version

[an] AutoCAD drawing file compatible

[AutoCAD Release 10] or a[n ACSII] DXF format drawing interchange file compatible with AutoCAD

[Release 10].

The following shall be on the plans submitted:

( ) Entire tract shown on one sheet

( ) Plat based on a new or existing survey of the property being subdivided, tied into N.J. State plane coordinate system of 1983 as per revised statutes title 45:8

( ) Plans signed and scaled by a New Jersey Licensed Land Surveyor

( ) The tract name, tax map sheet, block and lot number, date, reference meridian, scale and the following names and addresses:

( ) The record owner or owners

( ) The subdivider

( ) The person who prepared the map

( ) Acreage of tract to be subdivided to the nearest hundredth of an acre

( ) Accurate length of all existing and proposed lot lines

( ) Tract boundary lines, right-of-way lines of streets, street names, easements and other rights-of-way. land to be reserved or dedicated to public use, all lot lines and other site lines; with accurate dimensions, bearings or deflection angles, and radii, arcs and central angles of all curves.

( ) The purpose of any easement or land reserved or dedicated to public use shall be designated, and the proposed use of sites other than residential shall be noted.

( ) Each block and the lots within each block numbered in accordance with a numbering system provided by the Municipal Engineer

( ) Minimum building setback line on all lots and other sites

( ) Location and description of all existing and proposed monuments

( ) Names of owners of adjoining land

( ) Certification by a Licensed New Jersey Land Surveyor as to the accuracy of details of the plat, as required by law

( ) Certification that the applicant is agent or owner of the land or that the owner has given consent under an option agreement

( ) When approval of a plat is required by an officer or body of such municipality, county or state, approval shall be certified on the plat

( ) Cross sections and profiles of streets, approved by the Township Engineer

( ) Plans and profiles of storm and sanitary sewers, water mains and hydrants approved by the Township Engineer, Health Officer and Sewerage Authority. All plans and profiles for gas, electric and telephone utilities are to be approved by the appropriate utility company.

( ) Final grading plans showing two foot contours, the proposed solutions to difficult drainage problems that might be encountered as a result of the finished grades and the location and elevation of the main levels of each building.

BULK VARIANCE CHECKLIST

( ) Original and 12

[

10] copies of application forms

( ) Application form signed and notarized

( ) Owners Consent (if applicable

( ) Application fee

( ) Escrow fee (if applicable)

( ) Signed escrow release form (if applicable)

( ) Signed authorization form

( ) A

[

Three (3)] complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) 12 copies of variance plan

( ) Plans collated, stapled, folded to a dimension not to exceed 10" x 12"

( ) Copy of protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) "Letter of Intent" detailing size of proposed building, proposed use, number of tenants, number of employees, anticipated hours of operation, traffic, etc.

( ) Evidence of soil erosion and sediment control plan submittal to Freehold Soil Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit or determination (if applicable)

( ) A statement indicating that the property which is the subject of the application for development is free of delineation as a freshwater wetland, as more particularly defined in N.J.S.A. 13:9B-3 et seq, or if any part of the property which is the subject of the application for development. is delineated as "freshwater wetland", then the applicant shall show such areas on a survey of the property, prepared by a licensed surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Any other documents deemed necessary for a thorough review, as required by the Department of Planning and Engineering. These additional documents may include, but are not limited to, descriptive indications of ingress and egress, parking, walkways, fencing, drainage, exterior lighting, building floor plans, front, side and rear elevations, freestanding signs and landscaping.

The following shall be on variance plans submitted:

( ) Survey of the property, prepared by a Professional Land Surveyor of the State of New Jersey showing:

a. Boundaries of the property

b. Building and setback lines and the lines of all existing streets, roads, reservations, easements, right-of-ways and areas dedicated to public use, within two hundred (200) feet of the property

c. Title, reference meridian, scale

d. Name and address of record owner

e. Name, address, professional license number and seal of the surveyor who prepared the survey

( ) Existing and proposed buildings and structures with accurate dimensions to reflect distances to property lines and to both sidewalk and curbline

( ) Floor plans and elevations

USE VARIANCE CHECKLIST

( ) Original and 15 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent (if applicable)

( ) Application fee

( ) Escrow fee (if applicable)

( ) Signed escrow release form (if applicable)

( ) Signed authorization form

( ) A complete "Tax and Assessment Payment Report" form which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) 15 copies of variance plan

The following shall be on variance plans submitted:

( ) Survey of the property, prepared by a Professional Land Surveyor of the State of New Jersey showing:

a. Boundaries of the property

b. Building and setback lines and the lines of all existing streets, roads, reservations, easements, right-of-ways and areas dedicated to public use, within two hundred (200) feet of the property

c. Title, reference meridian, scale

d. Name and address of record owner

e. Name, address, professional license number and seal of the surveyor who prepared the survey

The following shall be on the plans submitted:

( ) Key map showing site and its relation to surrounding area

( ) Plans certified by appropriate professional as stipulated by New Jersey revised statutes Title 45:8, 13:40-7.1 et seq

( ) Zone data

( ) Location of all existing and proposed buildings or structures with spot elevations

( ) Names of all owners of record of all adjoining property, and property directly across the street or streets from the property involved, and the block and lot numbers of all the property shown on the plan

( ) Location of all existing and proposed storm drainage structures and utility lines including telephone, power, water, sewer, gas, etc., whether publicly or privately owned, with pipe sizes, grades and direction of flow

( ) Proposed use or uses of land and buildings, including outdoor storage

( ) Size and location of all driveways and curb cuts

( ) Parking and loading layout

( ) Total number of parking or loading spaces

( ) Dimensions of parking or loading spaces, aisles and parking islands

( ) Dimensions of all building setbacks and yards

( ) Percent total impervious coverage

( ) Percent total building coverage

( ) Building dimensions

( ) Area and height of proposed and existing buildings or structures

( ) The location and size of existing and proposed signs

( ) Existing and proposed screening and landscaping

( ) Existing wooded areas

( ) Critical areas

( ) Plans collated, stapled, folded to a dimension not to exceed 10" x 12"



( ) Copy of protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) "Letter of Intent" detailing size of proposed building, proposed use, number of tenants, number of employees, anticipated hours of operation, traffic, etc.

( ) Evidence of soil erosion and sediment control plan submittal to Freehold So'] Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Transportation for Route 18 Access Pen-nit and

( ) Drainage Permit (Route 18 properties only)

( ) Traffic study, including anticipated traffic volumes, capacity of existing or proposed roads, traffic impact on road network and need for traffic improvements

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit or determination (if applicable)

( ) A Letter of Interpretation from New Jersey Department of Environmental Protection Freshwater Wetlands Division, including evidence that notice was given to the Municipal Clerk pursuant to N.J.S.A. 13:9B. If the New Jersey Department of Environmental Protection deems that wetlands are present, or the applicant does not receive a response to its request for a letter of interpretation, the applicant shall show such areas on a survey of the property. prepared by a Licensed Surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Environmental Impact Assessment Report in accordance with Town Code Section 132-31

( ) Any other documents deemed necessary for a thorough review, as required by the Department of Planning and Engineering. These additional documents may include, but are not limited to, descriptive indications of ingress and egress, parking, walkways, fencing, drainage, exterior lighting, building floor plans, front, side and rear elevations, freestanding signs and landscaping.

( ) Floor plans and elevations

( ) Site map including site layout and pertinent site features on CAD-generated data file submitted on diskette(s), 3.50"/1.44Mb formatted for DOS Version 3.x based IBM PC's and PC compatibles. The file shall be either the most current version AutoCAD drawing File compatible or a DXF format drawing interchange file compatible with AutoCAD.

PRELIMINARY P.U.R.D. CHECKLIST

( ) Original and 14 copies of application forms

( ) Application form signed and notarized

( ) Owners Consent

( ) 15 complete sets of preliminary plat

( ) 11 copies of lot layout (excluding details and construction plans)

( ) Scale not less than 1" to 100'

( ) Plans collated, stapled, folded to a dimension not to exceed IO x 12

( ) Plans no greater than 36" x 42" size

( ) Application fee

( ) Escrow fee

( ) Signed escrow release form

( ) Signed authorization form

( ) Three (3) complete "Tax and Assessment Payment Report" forms which will be forwarded to the Collector of Revenue office for verification that no delinquent taxes or assessments are due

( ) Survey of property, prepared by a licensed surveyor of the State of New Jersey showing:

a. Boundaries of the property

b. Building and setback lines and the lines of all existing streets, roads, reservations, easements, right-of-ways and areas dedicated to public use, within two hundred (200) feet of the property

c. Title, reference meridian, scale

d. Name and address of record owner

e. Name, address, professional license number and seal of the surveyor who prepared the survey

The following shall be on the plans submitted:

( ) Key map showing site and its relation to surrounding area

( ) Plat based on a new or existing survey of the property being subdivided, tied into N.J. State plane coordinate system of 1983 as per revised statutes title 45:8

( ) Plans signed and sealed by a New Jersey Licensed Land Surveyor (survey data only) and by a New Jersey Licensed Engineer if engineering has been performed

( ) Zone data table

( ) The tract name, tax map sheet, block and lot number, date. reference meridian, scale and the following names and addresses:

( ) The record owner or owners

( ) The subdivider

( ) The person who prepared the map

( ) Acreage of tract to be subdivided to the nearest hundredth of an acre

( ) Proposed lot lines

( ) Existing lot lines to remain

( ) Existing lot lines to be removed

( ) Setback distance of all existing and proposed structures from each lot line

( ) Area of lots shown to nearest square foot

( ) Existing and proposed streets, sidewalks, storm drains, radii, curbs, bridges, culverts

( ) Natural features, such as wooded areas and rock formations

( ) Existing and proposed structures

( ) Existing and proposed screening and landscaping, including a planting plan, with quantity, species, caliper and location of planting noted

( ) All existing schools, zoning and special district boundaries within two hundred (200) feet of the property. Such features shall be shown on a separate map or as a key map on the detailed map itself.

( ) Location of existing trees with caliper of 4 [6] inches d.b.h. or more

( ) Existing and proposed contours at 1 foot intervals based on National Geodetic Vertical Datum 1988 [1929] to determine general slope and natural drainage of the land. Where necessary to evaluate drainage, the Board shall require contours to be shown for all lands within 200 feet of the property in question.

( ) High and low points of all proposed streets, proposed cross sections and centerline profiles of all proposed streets

( ) Existing and proposed easements

( ) The distances, as measured along the centerlines of existing streets abutting the property to the nearest intersection with any public street

( ) Location of existing edge of pavement and proposed edge of pavement of all roadways abutting site

( ) Location of all existing and proposed storm drainage structures and utility lines including telephone, power, water, sewer, gas, etc., whether publicly or privately owned, with pipe sizes, grades and direction of flow

( ) Names of all owners of record of all adjoining property, and property directly across the street or streets from -the property involved, and the block and lot numbers of all the property shown on the plan

( ) Plans and profiles of all proposed utility layouts, including storm drainage, sanitary sewers and waterlines, showing feasible connections to existing utility systems or to proposed systems, which will be installed before the plat is submitted for final approval

( ) Statement of the steps to be taken by the subdivider to eliminate any downstream drainage problems which may be caused by the development of the subdivision and to mitigate impact from prior upstream development

( ) If fixtures other than Public Service Electric and Gas or Jersey Central Lighting, the location, direction of illumination and intensity of all outdoor lighting. Type of fixture and height of lighting are to be indicated and isolux lines are to be superimposed on the plan.

( ) Manufacturers catalogue cut sheet for proposed lighting

( ) Location of all land which lies within the 100 year flood line as depicted on the current State of New Jersey, Department of Environmental Protection, Division of Water Services, Bureau of Flood Plain Management, Delineation of Flood way and Flood Hazard Area Maps.

( ) Location of all areas with seasonal high-water table at the surface, including lakes and ponds.

( ) Location of all areas with seasonal high water table within one and a half (1 - ) feet of the surface.

( ) Location of all existing and proposed buildings or structures with spot elevations

( ) Proposed use or uses of land and buildings, including outdoor storage

( ) Size and location of all driveways and curb cuts proposed and on adjoining properties



( ) Cross sections and construction details of all streets, pavement, curb, sidewalks and walkways

( ) Parking and loading layout

( ) Total number of parking or loading spaces

( ) Dimensions of parking or loading spaces, aisles and parking islands

( ) Dimensions of all building setbacks and yards

( ) Percent total impervious coverage

( ) Percent total building coverage

( ) Building dimensions

( ) Area and height of proposed and existing buildings or structures

( ) Building elevations (each side) indicating materials to be used in construction

( ) The location, size, materials and construction details of existing and proposed signs

( ) Name, address, professional license number and seal of the architect, engineer, planner or surveyor preparing the site plan

( ) Refuse enclosure location and detail

( ) Fencing detail

( ) Percolation test and soil log results (if applicable) certified by New Jersey Licensed Professional Engineer

( ) Soil type

( ) Evidence of soil erosion and sediment control plan submittal to Freehold Soil Conservation Service (if disturbance of 5,000 square feet or more of soil)

( ) Evidence of submittal to New Jersey Department of Transportation for Route 18 Access Pen-nit and Drainage Permit (Route 18 properties only)

( ) Traffic study, including anticipated traffic volumes, capacity of existing or proposed roads, traffic impact on road network and need for traffic improvements

( ) Evidence of submittal to New Jersey Department of Environmental Protection for stream encroachment permit (if applicable)

( ) A Letter of Interpretation from N.J. Dept. of Environmental Protection Freshwater Wetlands Division, including evidence that notice was given to the Municipal Clerk pursuant to N.J.S.A. 13:9B. If the N.J. Dept. of Environmental Protection deems that wetlands are present, or the applicant does not receive a response to its request for a letter of interpretation, the applicant shall show such areas on a survey of the property, prepared by a Licensed Surveyor of the State of New Jersey.

( ) Evidence of submittal to Middlesex County Planning Board (if on County road or involving County drainage structure)

( ) Storm drainage calculations in accordance with Chapter 192

( ) Environmental Impact Assessment Report in accordance with Chapter 132

( ) Copy of any protective covenants or deed restrictions that are intended to cover all or any part of the tract

( ) A written statement setting forth the intentions of the applicant in regard to the proposed character of the subdivision, whether for the sole purpose of the sale of land or for the construction and sale of homes, with data as to the number, price range, size, floor plan and the outside design of homes, deed restrictions, date of beginning and completion of construction and proposed method of maintaining parking or recreational areas. The statement shall also contain an acknowledgment that the applicant is familiar with the Township's Look Alike Ordinance and Tree Removal Ordinance mid will abide by the terms of both ordinances.

( ) The density of land use to be allocated to various parts o the site.

( ) The location, type, standards and size of recreational and community facilities of all open space.

( ) The form or organization proposed to own and maintain common open space.

( ) The substance of any covenants, grants, easements, or any covenants proposed to be imposed upon the land or buildings, including easements for public utilities, to the extent known.

( ) The projected schedule for development and the appropriate times when final approvals would be requested.

( ) A statement of why the public interest would be served by the proposed development, such statement to be supported by a detailed economic, social and physical, study.

( ) The proposed number of bedrooms for all dwelling units.



( ) Delineation of pedestrian walkways, nature paths and bicycle paths, which must be in conformance to any adopted master plan for bicycle paths.

( ) Such other items and information pertaining to the site as the Department of Planning and Engineering reasonably determines would be necessary or helpful to the Planning Board in reviewing the application.

( ) Environmental Risk Audit in accordance with Township Code Chapter 132-58.1-I(2)

( ) Recycling Plan, which shall include details as to the storage, collection, disposition and recycling of recyclable materials as listed in Chapter 114.

( ) P.U.R.D. site map including layout and pertinent site features on CAD-generated data file submitted on diskette(s), 3.50"/1.44Mb formatted for DOS Version 3.x based IBM PC's and PC compatibles. The file shall be either the most current version AutoCAD drawing file compatible or a DXF format drawing interchange file compatible with AutoCAD.

Schedule B PROPOSED ORDINANCE AMENDMENT

Additions are underlined

Deletions are [bracketed]

Section 132-33. Escrow.

Escrow shall be deposited with the Township to cover the cost of all, professional services rendered to the municipality or approving authority for review of applications for development, review and preparation of documents, inspection of improvements or other purposes under the provisions of P.L. 1 975, c.291 (C.40:55D-1 et seq.). Prior to an application being ruled complete, the following sum(s) shall be submitted to be held in escrow:

Escrow shall be posted with the Township in cash, Certified Check or Money Order.

All funds shall be deposited by the Finance Officer in accordance with N.J.S.A. 40:55D-53.1

Schedule C PROPOSED ORDINANCE AMENDMENT

Additions are underlined

Deletions are

[

bracketed]

Section 132-54. As Built Requirements.



Prior to bond release for all residential improvements and all other improvements in the public right-of-way or public casements, "as-built" drawings shall be submitted to the Township Engineer. As-built plans shall be submitted on plastic film as well as a CAD generated data file (compatible with the most current version of AutoCAD) with a scale of no greater than 1" = 50'. All submittals must be referenced to the N.J. State Plane coordinate system of 1983 and the NAVD of 1988. As built plans [and] shall include the following:

**Webmasters Note: The previous section has been Added as per Ordinance No. 02-1.